Home » , » How To Integrate LTE eNode B

How To Integrate LTE eNode B

moshell 169.254.1.10 

lt all 

cvls 

As soon as I get back to the first license server (1001 is greater than the effect on the du B) 

cvset BasicCV_CXP102106%10_R9BE%2 

acc 0 manualrestart 
                 y
                 3 
                 0 
                 0 

SCRIPT 

trun script/102_new/
                    trun Doksan_eNB3/eNB_3_oam_tn.mo 
                    trun Doksan_eNB3/eNB_3_S1_setup.mo 
                    trun Doksan_eNB3/eNB_3_rn_mimo_cell31.mo 
                    trun Doksan_eNB3/eNB_3_rn_mimo_cell32.mo 
                    trun Doksan_eNB3/eNB_3_rn_mimo_cell33.mo 
                    trun Doksan_eNB3/systconst_enb3_MIMO.mo
                    trun Doksan_eNB3/systconst_enb3_tuning.mo 
                    trun Doksan_eNB3/eNB_3_oam_tn_lh0.mo 

acc RbsConfiguration=1 setUniqueLogicalName 
                    y 
                   2011L1A05N 

cvms script_yck 


LICENSE

secmode -f u
         rbs 

secmode -s 

acc 6 updateLicenseKeyFile
                 y 
                 lte 
                 lte 
                 169.254.1.12 
                 2011L1A05N_110621_080010.xml 

setclock 2011-07-19 08:36:30 

readclock


get feature

get . feature 

inv 

trun feature_setting_cellmme_unblock.mo 

                            (Dl64Qam = 1, DualAntDlPerfPkg = 1, Ul16Qam = 1 -> ENABLED and automatically change ACTIVATED) 

get . feature 

cvms license_yck 


ping test

acc IpAccessHostEt ping 
                     y 
                    169.254.1.12 

st mme 

st cell 

al 

How to get rid of the alarm?

 Min Password File Fault 
                 passwd ; rbs ; rbs


GPS

get . sync 

get sync 

cvms gps_yck 


Apply UP

pr upgrade 

cr SwManagement=1,UpgradePackage=CXP102051/12_R15AC 169.254.1.12 ./CXP102051%12_R15AC.xml 
             lte 
             lte 

lt all 

pr upgrade 

acl 448 

acc 448 nonBlockingForcedInstall 
             y 

polu 5 5 

lt all 

pr upgrade 

acl 448 

acc 448 rebootNodeUpgrade
             y 

polu 5 5 

cvls 

cvms pkg_yck 

get . finger 

st mme 

st cell 

al 


Environmental effect

trun Environment_alarm_setting.mo 
             1, 2 White, Blue Battery Door alarm
             3, 4 White, Orange CLU cable disconnected 
             5, 6 White, Green CLU Fault in unit 
             7, 8 White, Brown CLU Temperature out of specification 

al 

cvms Environment_alarm_yck 

trun 15AC_tuning.mo 

cvms Generalmo_ok yck none
Share this article :